BioSono provides a cyberspace (www.biosono.com) where researchers, engineers, and students can find useful reference and educational materials, conduct acoustic simulation, post questions on design and development, and get answers. The online KLM based transducer acoustic stack simulation, which is currently free, can help you choose piezoelectric, matching and backing material, and a tuning electrical network. The output from the model includes electrical transmit impedance, acoustic receive impedance, and the impulse or pulse-echo response. The ultrasound beam profile simulation provides the calculated transmitted ultrasound pressure field under certain excitation for a given transducer aperture in a number of different geometrical configurations, including circular elements (flat and concave piston), rectangular elements, linear arrays, convex arrays, and 2D arrays. The simulation is based on Field II, which is a free program that utilizes the spatial impulse response method, and has been validated by many researchers for accuracy. In addition to the web based acoustic simulation, we also provide pulse-echo system, transducers, and customized design and develop services.
Home
Ultrasound Probe
Ultrasound Electronics
Ultrasound Calculator
Transducer KLM Model Simulation
Beam Profile Simulation
Ultrasound Electronics
eZLab
Description
Specification
SonoLab Echo I
Description
Functional Diagram
Specification
Download
RF Generator
Description
Specification
Educational
Unipolar Transmitter
Bipolar Transmitter
Transceiver
Time Gain Control
Signal Conditioning
SonoLab Echo I Specification
Power Input
Voltage: 5v, USB type A
Current: 100mA
Frequency Characteristic
Testing range: 10k - 100MHz
Frequency scan minimal step: 1kHz
Scan step: 10 - 100
Frequency accuracy: 0.12Hz
Calibration
No calibration is required if the BNC connector is used directly.
If an extra fixture is used, the other fixture end need be calibrated at 0Ω, 50Ω, and 1kΩ. Regular high precision low inductance resistors can be used for calibration.
Impedance Range:
0 - 1k Ω: 2%, based on calibration resistor tolerance
Testing Waveform Characteristic
Amplitude: 200V
rms
Short circuit current: 2mA.
2-Ch Signal Generator
Waveform: sinusoidal wave
Phase difference between two channels: 0 -360 degree
Amplitude: 0.2V
rms
Short circuit current: 40 mA
Graphic User Interface
Matlab: R2012a or later version
Operating system: Windows 7
Dimensions: length: 7.5"; width: 5"; height: 2.5"
Environment: 10
o
C - 30
o
C
A 30 MHz Ultrasound Transducer
An 80kHz PZT Plate
50 ohm, 10kHz - 1 MHz
50 ohm, 1MHz - 100 MHz
100 ohm, 1MHz - 100 MHz
200 ohm, 1MHz - 100 MHz
1k ohm, 10kHz - 1 MHz
1k ohm, 1MHz - 100 MHz
Items included in the package
eZLab Impedance Analyzer hardware
A USB A-A cable
User manual
Price per unit: $1800.
Or email Contact@biosono.com for quotation.
Accessary
BNC 50 ohm teminator: $5.00
BNC 1k ohm teminator: $35.00
BNC 0 ohm teminator: $7.50
BNC to grab hook: $20.00
BNC to alligator: $25.00
BNC to SMA jack: $10.00
BNC to SMA plug: $20.00
© 2007-2023 BioSono Inc. All Rights Reserved.
Tel:510.378.1672. Fax: 510-338-9217. Email:contact@biosono.com