BioSono provides a cyberspace (www.biosono.com) where researchers, engineers, and students can find useful reference and educational materials, conduct acoustic simulation, post questions on design and development, and get answers. The online KLM based transducer acoustic stack simulation, which is currently free, can help you choose piezoelectric, matching and backing material, and a tuning electrical network. The output from the model includes electrical transmit impedance, acoustic receive impedance, and the impulse or pulse-echo response. The ultrasound beam profile simulation provides the calculated transmitted ultrasound pressure field under certain excitation for a given transducer aperture in a number of different geometrical configurations, including circular elements (flat and concave piston), rectangular elements, linear arrays, convex arrays, and 2D arrays. The simulation is based on Field II, which is a free program that utilizes the spatial impulse response method, and has been validated by many researchers for accuracy. In addition to the web based acoustic simulation, we also provide pulse-echo system, transducers, and customized design and develop services.
Home
Ultrasound Probe
Ultrasound Electronics
Ultrasound Calculator
Transducer KLM Model Simulation
Beam Profile Simulation
Free Version Beam Simulation
Beam Profile Simulation
Simulation List
Axial, Lateral 1D Beam Profile
No Parameter Variation
Vary Depth
Vary Frequency
Vary Transducer Bandwidth
2D Beam Profile
Axial-Lateral, Elevation=0
Axial-Lateral, Vary Elevation
Axial-Elevation, Lateral=0
Axial-Elevation, Vary Lateral
Lateral-Elevation at Focus
Lateral-Elevation, Vary Axial
Customized Simulation
Examples
1D Beam Profile
2D Beam Profile
Pulse Propagation
Images
Axial, Lateral 1D Beam Profile: No Parameter Variation
This simulation provides one-dimensional beam profile along axial, lateral, and azimuth angle, and a two-dimensional beam profile
One dimension simulation show the beam spatial resolution in axial, lateral, or azimuth angle quantitatively.
A 100x50 point rectangle area in front of the transducer covering both of the axial and lateral range used in one-dimension simulation will be calculated.
Output Results
Axial Profile
Lateral Profile
Azimuth Angle Profile
1D Scheme
2D profile
2D scheme
Excel Data File
This simulation generates 6 figure files and one MicroSoft Excel file including all the beam data. The files will be sent to you by email.
Click to see
Default Input Parameters for this Simulation
Click the figure to see the standard size figure
Order Input Information (Price: 99$):
Transducer Aperture: Loading...DIV APrt Loading...
Flat Round
Concave Round
Flat Doughnut
Concave Doughnut
Flat Rectangle
Concave Rectangle
Flat Linear Array
Radius
mm
Curvature Radius
mm
Frequency:
MHz
© 2007-2023 BioSono Inc. All Rights Reserved.
Tel:510.378.1672. Fax: 510-338-9217. Email:contact@biosono.com